As AutoOn is motion detector by microwave sensor, this is electric saving device which reduce the amount of electricity as turn on and off the lamps automatically to detect human and object’s motion
Product Features
It can be applicable to all the lamps.
It can detect moving objects more than 20m and insensitive to dust, light, and ambient temperature etc.
The attached CdS detects environmental light not to turn on the lamps to reduce unnecessary lighting.
The electric instruments can be used in parallel connection if the overall power consumption of used electric instruments don’t exceed 1,100W. The case when the power consumption in more than 1,100W, an external solid state relay should be used additionally to switching the devices.
The detection range can be adjusted according to the area of the application. The coverage can be widened unlimitedly by parallel connection of AutoOn’s.
Major characteristics
Indoor use / compatible with various types of lights
Hardly affected by external environmental factors, such as temperature/humidity/dust/light (accurate sensing, application in various locations and areas)
Ability to sense all moving objects : optimized for underground parking lots
Penetration : penetrates non-metal partition (glass, screen, plywood) to sense motion on the opposite site, optimized for toilets
Application
Automatic light control system: toilet/hallway/stairs/entrance/underground parking lot/hall
Security warning light, invader sensing audio
Automatic door / escalator control
Automatic cooling/heating control system
Specification
Item
Specification
Factory setting
Note
Voltage
Single phase 110~220VAC, 50~60Hz
-
-
Controllable Instruments
Every electric instruments
-
-
Power consumption
1,100W max
-
1,000W for inductive loads
Unlimited using external SSR
VR1
Coverage
CW ->decrease
CCW -> increase
Max coverage
Coverage : 5~20m
VR2
Brightness
CW-> operates at lighter environment
CCW -> operated at darker environment
Always operates
min : always operates
max : operates at dark
/ 1Lux~1500Lux
VR3
Time
CW -> decrease
CCW -> increase
5min
1sec~10min
linear per each
Electric wires
Black/Yellow/Red Wire
-
-
Angle Control
Up/Down, Left/Right
-
-
Switch
On -> Use Auto
On/Off -> Bypass
ON
(Automatic Control)
-
Installation
On the ceiling
-
-
Sensor settings
1. First, AutoOn's switch set up to "On" after sensor front view set up to wanted main direction.
2. You have to come out from installed place after set up to 1 sec. on time, Brightness 1,500Lux, Coverage over middle for check normal operations. (If you stand on sensor front, sensor will be detect you continuously)
3. When time setting is 1 sec. you can see to turn off lamps after 1 sec. on condition of no detection.
4. After check normal operations, you must check more about dead zone(ex, toilet interior) or outside. If there are many dead zone, you must turn to right and detect on maximum. If sensor detects outside place, you must turn to left for mal-function prevention.
5. After complete coverage control, then set up time, and close control cover.