As Auto mini is motion detector by microwave sensor, this is electric saving device by turn on and off the lamps automatically to detect human and object’s motion.
Application
Automatic lamp control of stairs or hallway
Product Features
It can be applicable to all the lamps.
It can detect moving objects more than 5m and insensitive to dust, light and ambient temperature etc.
The attached CdS detects environmental light not to turn on the lamps to reduce unnecessary lighting.
It can be use any electric products within not exceed 100W.
If exceed 100W, you use SSR(Solid State Relay) switch.
Installation Pictures
AutoOn Mini Instruction
Specification of product and Control function
Item
Specification
Setting
Remark
Service voltage
Single phase
220VAC, 50~60Hz
-
Applicable lighting
apparatus
All lighting apparatus
operated with AC power
-
Load
100W
-
Max 300
Slide
switch 1,2
Lighting
time
Time1
Time2
Time
Time1 : Left
Time2 : Left
1sec~5min
Left
Left
1sec
Right
Left
30sec
Left
Right
1min
Right
Right
5min
Slide
swtich 3
Coverage
Left -> Maximum limit
Right -> Minimum limit
Left
Max sensing range : Radius over w.5m
(at height 2.5m)
Slide
swtich 4
Brightness
Left -> Automatic
lighting at darkness
Right -> Automatic
lighting at any time
Right
Darkness Condition : 10Lux
Wire
Black : Power for sensor
Yellow : Power for lamp
-
4 lines
Installation
Horizontal installation on ceiling
-
Checking methods are as follows.
Initial control : Set both of the slide switch 1 (Time1) and 2(Time2) to left to be minimum time and set the slide switch (Coverage) in proper value, and then set the slide switch 4 (Brightness) to right to be lighted at any time.
Installation : Install at your desired location.
Wire connection : Connect 220VAC power to two black lines, and connect an incandescent or fluorescent lamp for testing to a pare of yellow lines.
Wait for 5 seconds after turn on power. (Normal sensing begins after 5 seconds from turn on power)
Checking the sensing range : Check the sensing range by the flickering status of the lighting apparatus as actual movement. Adjust the location of any problem in location and adjust the slide switch 3 (Coverage) if the sensitivity is excessive of short.
Selection of brightness for sensing : Determine whether automatic lighting regardless of brightness or automatic lighting only at darkness by adjusting the slide switch4.
Set the desirable light time by adjusting the slide switch 1 (Time 1) and the slide switch 2 (Time2). Recommendable time is generally 1 minute, and especially for a fluorescent lamp, it is generally economical to prevent rapid reduction of life by unnecessary flickering.